- Products
- Precision gages
- MarCal - Calipers
- MarCal - Digital calipers
- MarCal 16 EWR-X - Digital Caliper for special applications, IP 67
- MarCal 16 EWR-AA - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-AI - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-AR - Digital Caliper for special applications, IP 67
- MarCal 16 EWR-BA - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-C - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-H - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-LI - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-NA - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-RW - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-S - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-SA - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-SI - Digital Caliper for special applications, IP 67, Data interface
- MarCal 16 EWR-SM - Digital Caliper for special applications, IP 67, Data interface
- MarCal - Vernier calipers
- MarCal - Dial calipers
- Micromar - Micrometers
- MarTest - Test Indicators and Touch Probes
- MarCator - Digital and Dial Indicators
- MarCator 1075 R / 1086 R / 1087 R / 1088 - Digital indicator
- MarCator 803 / 805 / 810 - Mechanical dial indicators
- MarCator - Mechanical dial indicators ANSI/AGD
- MarCator - Dial indicator, ANSI/AGD Group 0
- MarCator - Dial indicator ANSI/AGD Group 1
- MarCator - Dial indicator ANSI/AGD Group 2
- MarCator - Dial indicator ANSI/AGD Group 3
- MarCator - Dial indicator ANSI/AGD Group 4
- MarCator - Long-range indicators
- MarCator - Dial indicators with limited measuring range
- MarCator - Perpendicular dial indicators
- Millimess - Digital and Dial Comparators
- MarStand - Indicator Stands, Comparator Stands, Run out Testing Instruments
- Marameter - Indicating Measuring Instruments
- Multimar - Universal Measuring Instruments
- MarConnect - Data Processing
- MarTool - Measuring and Inspection Equipment
- MarGage - Standards, Gages and Gage Blocks
- MarCal - Calipers
- Millimar - Electrical Length Measuring Instruments and Multi-Gaging Metrology
- Millimar - Indication and evaluation instruments
- Millimar - Inductive probe
- Millimar 1301 / 1303 - Inductive probe
- Millimar 1304 K - Inductive probe
- Millimar 1318 - Inductive probe
- Millimar 1340 - Inductive probe
- Millimar P1300 - Inductive probe
- Millimar P2000 - Inductive probe
- Millimar inductive indicator probes - Inductive probe
- Millimar measuring heads with parallel spring-loaded system - Inductive probe
- Millimar - Air gages
- Millimar - Electronic levels
- Digimar - Height Gages
- MarVision - Optical Measuring Instruments
- MarSurf - Mobile Roughness Measuring Units
- MarSurf - PC-Based Roughness Measuring Units
- MarSurf - Contour Measuring Units
- MarSurf - Automatic Roughness and Contour Measuring Systems
- MarSurf - Optical Measuring Units
- MarForm - Table Formtesters
- MarForm - Reference Formtester
- MarForm - Applications
- Precimar - Gage Block and Dial Gage Testing Unit
- Precimar - Workshop and Setting Units
- Precimar - Universal and High End Length Measuring Units
- MarShaft - Optical and Tactile Shaft Measuring Units
- MarGear - Gear Measuring Units
- MarOpto - Measuring Devices for Optics Industry
- MarOpto - Applications
- MarWin - Software platform
- MarSolution - Our Visions
- MarSolution - Applications
- MarSolution - Measuring Devices based on Millimar
- Precision gages
- Applications
- Know-how
- Application Tips
- Gaging Tips
- Subscribe to Gaging Tips
- Indicator Gaging Tips
- Basics of Measurement Gaging Tips
- Surface Measurement Gaging Tips
- Electronics Gaging Tips
- Calibration Gaging Tips
- Hole Measurement Gaging Tips
- SPC Basics Gaging Tips
- Machine Calibration Gaging Tips
- Gageblocks Gaging Tips
- Geometry Gaging Tips
- Air Gaging Tips
- Automatic Gaging Tips
- Hand Tools Gaging Tips
- Application Gaging Tips
- Industry 4.0
- Mahr Parameter
- Mahr Academy
- MarWin
- Request probe arm data sheets
- Promotional Activities
- The news and practice blog
- Mahr RoadShow
- Services & Support
- Mahr Academy

Enter your phone number in the callback form and we will return your call at the requested time.
Supplier’s Test Summary for Lithium Cells in accordance with UN 38.3
Manufacturers must subject lithium batteries and lithium cells to various safety tests before they can be placed on the market. This includes the so-called UN 38.3 test. This test simulates transport conditions such as pressure, temperature, crushing, impact, etc. In the "Manual of Tests and Criteria" of the United Nations in Part III, Section 38.3, this is described with 8 test modules, which in some documents and data sheets are also referred to as T.1 to T.8 test.
From 01 January 2020, manufacturers and distributors along the entire transport chain are obliged to provide a test summary of this "38.3 test" to every natural and legal person in the supply chain. The test report must have been available since 2000, but this was never part of the logistics operation. Since January 1, 2020, this has been part of the dangerous goods regulations and part of the supply chain. The basis for this is the revision of ADR/RID/ADN 2019, sub-chapter 2.2.9.1.7 “g”, which states that "Manufacturers and distributors of cells or batteries manufactured after 30 June 2003 must provide the test summary specified in the Manual of Tests and Criteria, Part III, sub-section 38.3, paragraph 38.3.5".
The same requirement applies to maritime and air transport. Here too, the IMDG Code or IATA DGR stipulates that the 38.3 test must be provided by the confirmed test summary. Each client for a transport is obliged to check whether a test summary is available, this is required by law. When placing an order, each consignor must ensure that the conditions for transport are met.
In the product list available on the right as a download, we fulfil our obligation and link for you all test summaries of the battery manufacturers we use for the product. If you have any further questions, our technical advisors are at your disposal.